CIP200/300-300 Main Technical Qualifications
- Equipment Name: Cold Isostatic Press
- Equipment type: CIP200/300-300
- Maximum Design pressure: 300MPa
- Suggested max working pressure: 270mpa
- The effective inner diameter of suppress cylinder vessel: Ø 200mm
- The effective inner height of suppress cylinder vessel: 300mm
- Pressing system Working medium : Emulsion(Buyer's own preparation according to requirement)
- Pressing system driving medium : L-HM32 anti-wear hydraulic oil(Buyer's own preparation)
- No working parts pressure rising time: 0~300MPa,t≤ 2min
- Assistant time: upper plug close+ frame move in:t≤ 1.5min upper plug open+frame remove : t≤ 1.5min
- pressure hold time : 0~9999s Setting freely
- pressure falls during pressure holding : hold 30min,falls≤2% (pressure setable self-compensation automatically )
- Control mode: PLC(Siemens)+HMI(MCGS) / Automatic and Manual mode
- Supercharging mode: one - time supercharger , gradable pause
- Pressure relief mode: Automatic pressure relief, gradable pause
- Loading mode: the upper plug drives the feeding cage to move
- By CE Certificated with PED directive
- Install Way: on floor
- Power Supply system: 50Hz, 380V, Three-phase five wire system
- Working condition : 0 ºC~ 45 ºC, Relative Humidity not more than 90%
- Install Power : ≈ 15 kw
- Install area: ≈ 6-8 m2
- Running noise: ≤ 75dB
Our main type of press is as follows:
1. Cold Isostatic Press:
S.NO. |
Type |
Diameter of Pressure
Vessel |
Depth of Pressure
Vessel |
Maximum Isostatic
Pressure |
1 |
CIP 200/300-300 |
200mm |
300mm |
300Mpa |
2 |
CIP 200/1000-300 |
200 mm |
1000mm |
300Mpa |
3 |
CIP 420/4000-320 |
420mm |
4000mm |
320Mpa |
4 |
CIP 500/1200-400 |
500mm |
1200mm |
400Mpa |
5 |
CIP 500/1500-300 |
500mm |
1500mm |
300Mpa |
6 |
CIP 710/2000-250 |
710mm |
2000mm |
250Mpa |
7 |
CIP 1000/3500-200 |
1000mm |
3500mm |
200Mpa |
a. The vessel inner materials is 34CrNi3MoV alloy whole parts forged and then The forged vessel be wire wounded by alloy of wire(65Mn steel 1.5mm x 6mm size) as per the designed.
b.Whole procedure of the
cold isostatic pressing (CIP) machine, increasing, holding and releasing pressure is controlled by PLC and also there is a decompression system to protect the system over pressure to keep the machine in safety running
2. Hot Isostatic Press:
S.NO. |
Type |
Diameter of
Pressure Vessel |
Height of
Pressure Vessel |
Pressure |
Temperature |
1 |
HIP 800/1200-150/1000 |
800mm |
1200mm |
150Mpa |
1000degrees |
2 |
HIP 1250/2000-200/1400 |
1250mm |
2000mm |
200Mpa |
1400degrees |
3. Warm Isostatic Press:
S.NO. |
Type |
Diameter of
Vessel |
Length of
Vessel |
Pressure |
Temperature |
1 |
WIP D500-L2000/P200mpa-T300 |
500mm |
2000mm |
200Mpa |
300degrees |
2 |
WIP D300-L1500/P250mpa-T200 |
300mm |
1500mm |
250Mpa |
200degrees |
3 |
WIP D630-L2000/P250mpa-T300 |
630 mm |
2000mm |
250Mpa |
300degrees |
a.The vessel inner materials of WIP is 34CrNi3MoV alloy whole parts forged and then The forged vessel be wire wounded by alloy of wire(65Mn steel 1.5mm x 6mm size) as per the designed.
b.Whole procedure of the
warm isostatic press machine (WIP ) , increasing, holding and releasing pressure is controlled by PLC and also there is a decompression system to protect the system over pressure to keep the machine in safety running.
Contact Us:
Marketing Manager: |
George Sun |
|
|
|
|
Website: |
chinasun99.en.made-in-china.com |
Address: |